Why is my Navien tankless leaking?
A Navien tankless usually leaks from one of five places: the pressure relief valve, the condensate drain, the cold water inlet filter, the recirculation inlet cap on A2 models, or a loose water fitting. A leaking heat exchanger is possible but much less common. Where the water shows up tells you a lot. On an NPE-A2, the built-in pump and 0.4 gallon buffer tank add two more fittings to check (Navien user's information manual).
Navien's installation manual calls for a 3/4-inch pressure-only relief valve rated for 150 psi or less on the hot outlet, and a free-draining condensate line (Navien NPE-2 installation manual). Most San Jose leak calls trace back to one of those two parts.
Where is the water coming from? A quick guide
Use this table before you call. A photo of the drip and the area under the unit helps us bring the right parts.
| Where you see water | Likely source | What it usually means |
|---|---|---|
| Pipe on the side, running to the floor or a drain | Pressure relief valve | Thermal expansion or high water pressure, or a worn valve |
| Clear water from a small PVC line under the unit | Condensate drain | Normal flow, or a clogged trap, line or neutralizer if it backs up |
| Drips at the cold water inlet on the bottom | Inlet filter cap or O-ring | Cap loose or O-ring worn after a cleaning |
| Drips at the recirculation inlet on an NPE-A2 | Recirculation inlet cap | Cap loose or removed with no return line connected |
| Drips at isolation valves or unions | Valve packing or fitting | A loose union or a worn service valve |
| Water dripping from inside the cabinet | Internal fitting or heat exchanger | Needs a technician to open the unit and test |
Why does the Navien relief valve keep dripping?
A relief valve that drips now and then is usually reacting to thermal expansion in a closed water system. Navien's manual says periodic discharge may come from expansion in a closed supply and warns never to plug the valve. Many San Jose homes have a pressure regulator or backflow device that closes the system, so heated water has nowhere to go.
We measure your static water pressure, check the regulator and add or recharge an expansion tank if needed. The California Plumbing Code calls for a pressure regulator when street pressure is over 80 psi, and homes lower on a hillside street, such as parts of the Evergreen and Silver Creek foothills, can see higher pressure. If the valve itself is worn, we replace it with an approved 3/4-inch pressure-only valve. The discharge line should end 6 to 12 inches above a floor drain so any release is easy to see.
Is water from the condensate line normal?
Yes, a steady trickle from the condensate line is normal on a condensing Navien like the NPE-A2, NPE-S2 or NCB combi. The unit pulls so much heat from its exhaust that water condenses inside it. That water is acidic, so the manual says never to drink it or let pets drink it, and it recommends a neutralizer when the line runs to certain drains.
A problem shows up when the condensate cannot drain. A clogged trap, a kinked line, a line without a downward slope or a used-up neutralizer can back water up and push it out the bottom of the unit. We clear the trap, refill it with water as the manual requires, and replace the neutralizer media.
Can hard San Jose water cause a Navien leak?
Indirectly, yes. San Jose Water's 2025 report lists groundwater averaging 16.8 grains per gallon of hardness (San Jose Water 2025 report). Scale clogs the cold water inlet filter, and owners who clean it sometimes refit the cap with a twisted or dry O-ring. Scale also builds on valve seats, which can make a relief valve weep.
Long-term, heavy scale and overheating stress the heat exchanger. That is why we descale Navien units about once a year on San Jose Water groundwater and check the filter cap and O-ring on every visit. See Navien flush and descaling.
How we fix a Navien leak, step by step
Here is how a leak call runs for a San Jose home, from a Willow Glen garage to an Evergreen side yard.
- Text photos of the unit, the leak, the model plate and any error code to (669) 337-9311.
- We tell you whether to shut the water and gas off now and give a time window.
- On site, we dry the area and watch for the first drop to find the true source.
- We test water pressure and the expansion tank, and check the condensate trap and neutralizer.
- You approve the repair, then we replace the valve, O-ring, cap, fitting or part.
- We refill, restart and run the unit at high fire while checking every joint for leaks.
What to do right now if your Navien is leaking
Turn the unit off at its power button and close the cold water isolation valve below it. If water is spraying, close the main water valve to the house. Put a bucket or towels under the drip, and keep water away from the electrical outlet.
If you smell gas, leave the house and call PG&E or 911 from outside first. Do not try to open the cabinet yourself; Navien says only licensed professionals should install the relief valve, and improper work can void the warranty.
Is a Navien leak covered by warranty?
It depends on the part and the age of the unit. Navien's residential warranty covers the heat exchanger for longer than other parts, but freeze damage is not covered and improper maintenance can void coverage, according to the Navien user's information manual. Relief valves and condensate parts installed on site are usually not Navien parts at all.
Keep your model and serial number handy. We check coverage and handle any claim; see our Navien tankless warranty guide.
Navien leak repair across San Jose
We fix leaking Navien tankless units across San Jose, including Willow Glen, Almaden Valley, Evergreen, Berryessa, Cambrian, the Rose Garden, Blossom Valley, Silver Creek and Santa Teresa. Our shop is at 240 Bayview Ave in 95127. We also fix leaking Navien units in Santa Clara, Campbell, Cupertino, Los Gatos and Milpitas.
Navien tankless leaking FAQs
Why is my Navien tankless leaking from the bottom?
Most bottom leaks come from the condensate drain, the cold water inlet filter cap, the recirculation inlet cap on A2 models, or a loose isolation valve. A heat exchanger leak is less common. Dry the area, watch where the first drop forms, and text a photo to (669) 337-9311.
How much does it cost to fix a leaking Navien in San Jose?
The cost depends on the source. Replacing a relief valve, O-ring or filter cap is a small repair, while an internal part or heat exchanger costs more and may be covered by warranty. Efficient Water Heaters, Inc. finds the leak first and quotes before any work.
Is it safe to use my Navien while it is leaking?
A slow drip from the condensate line is normal and safe. Water from the relief valve, a fitting or inside the cabinet is not. Turn the unit off and close the cold water valve until we check it. If you smell gas, leave and call PG&E or 911 first.
How often should a Navien be serviced to prevent leaks?
Every 12 months on San Jose Water groundwater, which averages 16.8 grains of hardness. Each visit should include descaling, cleaning the inlet filter with a fresh O-ring, checking the condensate trap and neutralizer, and testing the relief valve.
How long does a Navien leak repair take?
Most valve, cap, O-ring and condensate repairs take 1 to 2 hours on site. Internal parts or a heat exchanger may need to be ordered, which can add days. We tell you how long before we start.
What is the difference between a condensate leak and a water leak?
Yes. Condensate is a normal byproduct of a condensing Navien and should flow steadily to a drain or neutralizer. A water leak comes from the supply, hot outlet or relief valve and is not normal. Condensate is acidic, so keep pets away from it.
Can a Navien leak damage my home?
Yes, if it goes unnoticed. A slow leak in a closet or garage can damage drywall, flooring and the outlet below the unit. A relief valve line that ends near a drain and a regular look under the unit catch problems early.
Book Navien tankless leak repair in San Jose
Call (669) 337-9311 with your Navien model and a photo of the leak. See also Navien tankless repair in San Jose and Navien error codes. You can check CSLB #1008381 on the state license site.
Call (669) 337-9311 · Send photos of the leak · Efficient Water Heaters, Inc. on Google Maps